SetAside Type | ||
Total Small Business Set-Aside (FAR 19.5) | ||
Solicitation ID | Solicitation Title | Solicitation Office |
W912CH25QA011 | Hydrogen Compressor / Gas Booster | |
Synopsis | ||
Compact Electric Hydrogen Compressor/Gas Booster, below are required specs to support the project.Electric gas booster/compressor for use to compress hydrogen.-Two-Stage.-Must be electrically driven with 220VAC/single phase power.-Gas inlet max pressure at 4,200 psi-Gas outlet max pressure at 12,500 psi-Include an inlet gas pressure reducers with bypass line and shutoff valve-Include pressure relief valve set at 11,500 psi-All vent ports must be connected to a common port separated for the relief and vent valves-Include a manual start/stop switch, hour meter, both inlet and outlet gauges, cooling fan, outlet shutoff valve-Must be under 160 lbs-Must be smaller than 38in x 12in x 24in .... Read More
|
||
Office Location | Agency Name | Solicitation Base Posting Type |
DEPARTMENT OF THE ARMY | Combined Synopsis/Solicitation |