4120--Replace 187 ton air cooled chiller at the Montgomery Regional Office

Posted Date: Nov 27, 2024
Due Date: Jan 16, 2025
Awarded Date: No Awarded Date
SetAside Type
Solicitation ID Solicitation Title Solicitation Office
36C10D25Q0020 4120--Replace 187 ton air cooled chiller at the Montgomery Regional Office
Synopsis
Preparation and Submission Instructions Quote Requirements - The following items shall be included in your submission: Cover Page with Solicitation Number, Project Title, points of contact, address, phone numbers, etc., and SAM Unique Entity ID Number (Contractors shall be registered in SAM - Home | SAM.gov) Response to Evaluation Factors: Factor 1 Technical Approach Factor 2 Technical Qualifications Sub-Factor 2(a) Specialized Experience and Technical Competence Sub-Factor 2(b) Key Personnel and Management Approach Factor 3 Relevant and Recent Past .... Read More
Office Location Agency Name Solicitation Base Posting Type
VETERANS AFFAIRS, DEPARTMENT OF Combined Synopsis/Solicitation
SetAside Type
Solicitation ID Solicitation Title Solicitation Office
36C10D25Q0020 4120--Replace 187 ton air cooled chiller at the Montgomery Regional Office
Synopsis
EVALUATION CRITERIA Factor 1 Technical Approach: 1. In a narrative format describe in detail how the offeror intends to meet or exceed all performance areas stated in the solicitation/statement of work/attachments that are related to Project Replace Chiller at VBA Montgomery Regional Office. NOTE: Vague, general narratives to include the restatement of the Statement of Work will be rated less favorably. 2. Identify the manufacturers of required equipment and provide the Specification Sheet for proposed replacement chiller, which satisfy the Buy-American Act and relate to this project. 3. Describe any technical difficulties .... Read More
Office Location Agency Name Solicitation Base Posting Type
VETERANS AFFAIRS, DEPARTMENT OF Combined Synopsis/Solicitation
SetAside Type
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-A
Solicitation ID Solicitation Title Solicitation Office
36C10D25Q0020 4120--Replace 187 ton air cooled chiller at the Montgomery Regional Office
Synopsis
4 STATEMENT OF WORK FOR CHILLER REPLACEMENT MONTGOMERY VA REGIONAL OFFICE DESCRIPTION: Replace 187-ton air cooled chiller PLACE OF PERFORMANCE: Montgomery VA Regional Office 345 Perryhill Road Montgomery, AL 36109 BACKGROUND: The Montgomery VA Regional Office air cooled chiller has begun to show signs of degradation in that one compressor has been replaced, Variable Speed Drive control board replaced, several refrigerant charge losses due to piping failure and evaporator seal failure. This unit is the only means of climate control and therefore is a vital system to the facility m1ss1on. SCOPE: .... Read More
Office Location Agency Name Solicitation Base Posting Type
VETERANS AFFAIRS, DEPARTMENT OF Presolicitation
An error has occurred. This application may no longer respond until reloaded. Reload 🗙